Image coming soon1 micron 1 ppm gecondenseerde perslucht coalescepilterbehuizingReliable filtration starts with verified specifications.
1 micron 1 ppm gecondenseerde perslucht coalescepilterbehuizing
Compressed Air Filter replacement element
Gecomprimeerd luchtfilter
1 micron 1 ppm gecondenseerde perslucht coalescepilterbehuizing
Orders are confirmed by our team for price, compatibility and delivery.
Verified specifications for confident selection.
Confirm installation requirements against the equipment manual or original documentation.
| Category | Gecomprimeerd luchtfilter |
|---|---|
| Equipment System | Air Compressor Systems |
| Filtratieclassificatie | 1-20 micron |
Coalescepilters: coalescepilters worden gebruikt voor het verwijderen van water en aerosolen.
Dampverwijderingsfilters: Dampverwijderingsfilters worden meestal gebruikt om gasvormige smeermiddelen te verwijderen die door het coalesceringsfilter gaan.
Drooge deeltjesfilters: droge deeltjesfilters worden meestal gebruikt om deeltjes te verwijderen na een adsorptiedoger.
Verontreinigingen kunnen de perslucht uit verschillende bronnen binnendringen. Inlaatlucht kan stof- of pollendeeltjes introduceren, terwijl gecorrodeerde leidingen schadelijke deeltjes kunnen toevoegen vanuit het compressorsysteem. Olie-aerosolen en dampen zijn vaak een bijproduct van het gebruik van olie-geïnjecteerde compressoren en moeten worden uitgefilterd vóór eindgebruik.
Als u de behoeften van uw persluchtsysteem kent, kan u het juiste filter kiezen.
De selectie van filterbeoordeling
| Filterbeoordeling | Filtertype | Filterdeeltjes (water en oliemist) | Olieverhoud |
| Klasse C | Botsingsscheiding | 3 micron | 5 ppm |
| Klasse T | Verdomd | 1 micron | 1 ppm |
| Klasse A | Verdomd | 0,01 micron | 0,01 ppm |
| Klasse F | Verdomd | 0,01 micron | 0,001 ppm |
| H graad (geactiveerde koolstof | Oliedampverwijdering | 0,01 micron | 0,001 ppm |
De filterselectie
| Filtermodel | Verbindingsgrootte | Filtergrootte | Stroom | ||
| C, t, a, f, h | RC | W mm | H1 mm | H2 mm | Ik m3/i |
| AP-*-001 | 1/2”, 3/4” | 98 | 213 | 236 | 1.2 |
| AP-*-002 | 3/4”, 1” | 98 | 213 | 236 | 2.4 |
| AP-*-003 | 1”, 1.5” | 117 | 253 | 286 | 3.8 |
| AP-*-005 | 1.5” | 117 | 382 | 415 | 5.8 |
| AP-*-008 | 1.5” | 117 | 382 | 415 | 8.5 |
| AP-*-010 | 2” | 133 | 509 | 550 | 10.2 |
| AP-*-013 | 2” | 133 | 509 | 550 | 13 |
| AP-*-015 | 2”, 2.5” | 150 | 675 | 715 | 15 |
| AP-*-018 | 2”, 2.5” | 150 | 782 | 830 | 20 |
| AP-*-022 | 2”, 2.5” | 150 | 936 | 985 | 25 |
Het flentype filter
| Filtermodel | Stroom | Verbindingsgrootte | Aantal element | Filtergrootte | |||
| C, t, a, f, h | Ik m3/i | RC | Pc's | W mm | H1 mm | H2 mm | D mm (binnendiameter) |
| AFP-*-020 | 20 | DN65 | 1 | 300 | 770 | 940 | 125 |
| AFP-*-025 | 25 | DN80 | 1 | 336 | 943 | 1118 | 150 |
| AFP-*-030 | 30 | DN100 | 2 | 500 | 1050 | 1250 | 207 |
| AFP-*-040 | 40 | DN100 | 2 | 500 | 1050 | 1250 | 207 |
| AFP-*-060 | 60 | DN100 | 3 | 500 | 1050 | 1250 | 259 |
| AFP-*-080 | 80 | DN125 | 4 | 600 | 990 | 1250 | 350 |
| AFP-*-100 | 100 | DN125 | 5 | 600 | 990 | 1250 | 350 |
| AFP-*-120 | 120 | DN125 | 6 | 600 | 1070 | 1350 | 350 |
| AFP-*-140 | 140 | DN150 | 7 | 630 | 1020 | 1350 | 400 |
| AFP-*-160 | 160 | DN150 | 8 | 700 | 1020 | 1350 | 450 |
| AFP-*-180 | 180 | DN150 | 9 | 780 | 1070 | 1400 | 500 |
| AFP-*-200 | 200 | DN150 | 10 | 780 | 1070 | 1400 | 550 |
| AFP-*-250 | 250 | DN200 | 13 | 780 | 1130 | 1460 | 550 |
Installation Notes
Stop the system and release pressure before removal. Confirm flow direction and sealing surfaces before installation.
Maintenance & Replacement
Replace according to pressure drop or the maintenance schedule. Inspect for leakage and seal damage.
Before Ordering
Confirm medium, flow rate, pressure, temperature, connection and available installation space.
Delivery Options
Shipping or service point pickup. Our team confirms the best arrangement based on destination, weight and lead time.
Confirmed Before Dispatch
After inquiry, we verify specifications, price and supply status before delivery.
Ongoing Support
For specification, installation or quality questions, keep the product and order information available when contacting us.
INQUIRYSend an inquiry for this product
Send your requirements for 1 micron 1ppm condensed compressed air coalescing filter housing and our selection team will confirm compatibility, price and lead time.
Veelgestelde vragen
How do I confirm compatibility without a third-party brand reference?
Provide the product number, dimensions, connection details, operating conditions and equipment information. Our team will confirm the application.
Which dimensions should I measure?
Measure the overall height, outer diameter, inner diameter and thread or connection size. A photo or drawing helps confirm the replacement.
How do I choose the correct seal material?
Seal selection depends on the filtration media, operating temperature and chemical compatibility. We can confirm suitable options for your application.
Can you provide a product data sheet?
Yes. Send the product number and required specifications and we will provide the available data sheet and selection support.